Please refer to the main Schedule of Products page for more information.

Pipes - Plastic

Product type

Product scope/application

Specification

Year

Lead Free Applies

Acrylonitrile butadiene styrene (ABS) pipe

 

Acrylonitrile butadiene styrene (ABS) compounds (ABS 120, ABS 140, ABS 160 and ABS 180), pipes for the conveyance of liquids under pressure.

AS/NZS 3518 Acrylonitrile butadine styrene (ABS) compounds, pipes and fittings for pressure applications

2013

No

Acrylonitrile butadiene styrene (ABS) piping system for the conveyance of water under pressure for use at continuous operating temperatures up to 70°C, allowable operating pressures up to 1600 kPa in sizes ranging from DN 20 to 110 for use with ABS fittings.

WMTS-507 Acrylonitrile Butadiene Styrene (ABS) Piping System with Stainless Steel Lining for Plumbing Water Service Applications

2014

 

No

Cross-linked polyethylene pipe

Cross-linked polyethylene pipes for the conveyance of fluids under pressure including: water, wastewater and slurries.

AS 2492 Cross-linked polyethylene (PE-X) pipes for pressure applications

Note: See NoD 2017/4.3

2007

No

Macro composite pipe

Multilayer piping systems intended to be used for heated and cold water installations inside buildings.

AS 4176.2 Multilayer piping systems for hot and cold water plumbing applications – pipes

Note: See NoD 2017/4.3

2010

No

Polybutylene (PB) pipe

Polybutylene pipe of pressure class PN16 up to 28 mm nominal outside diameter for heated and cold water applications.

Note: This does not apply to pipes with a wall thickness of less than 1.6 mm.

AS/NZS 2642.2 Polybutylene (PB) plumbing pipe systems Polybutylene (PB) pipe for hot and cold water applications

Note: See NoD 2017/4.3

 

2008

No

Polyethylene (PE) pipe

 

 

Polyethylene pipes for the conveyance of fluids under pressure including, but are not restricted to, water, wastewater, slurries.

AS/NZS 4130 Polyethylene (PE) pipes for pressure applications

 

2018

No

Solid-wall polyethylene (PE) pipes for soil and waste discharge (low and high temperature) of nominal sizes DN 32 to DN 315 for installation inside buildings

Note: Pipework intended to be buried is outside of the scope.  

AS/NZS 4401 Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings - Polyethylene (PE)

Note: See NoD 2017/4.3

2006

No

Polyethylene (PE) pipes greater than DN 100 for sewerage and drainage applications, above and below ground, inside and outside of buildings, and intended to be used where the pipeline is operating under gravity flow and the operating pressure is low. It includes plain and structured wall pipes.

AS/NZS 5065 Polyethylene and polypropylene pipes and fittings for drainage and sewerage applications

Note: See NoD 2017/4.3

2005

No

Polypropylene (PP) pipe

 

Polypropylene (PP) piping systems intended to be used for heated and cold water installations within buildings.

ISO 15874-1 Plastic piping systems for hot and cold water installations – Polypropylene (PP) - General.

2013

No

Polypropylene (PP) for piping systems intended to be used for heated and cold water installations within buildings.

ISO 15874-2 Plastics piping systems for hot and cold water installations – Polypropylene (PP) – Pipes

Note: See NoD 2017/4.3

2013

No

Solid-wall polypropylene (PP) pipes for soil and waste discharge (low and high temperature) inside buildings.

Note: Pipework intended to be buried is outside of the scope. 

AS/NZS 7671 Plastics piping systems for soil and waste discharge (low and high temperature) inside buildings

2010

No

Polypropylene (PP) pipes greater than DN 100 for sewerage and drainage applications intended to be used where the pipeline is operating under gravity flow and the operating pressure is low. It includes plain and structured wall pipes.

AS/NZS 5065 Polyethylene and polypropylene pipes and fittings for drainage and sewerage applications

Note: See NoD 2017/4.3

2005

No

Polyvinyl chloride (PVC) pipe

PVC pipes for pressure applications.

AS/NZS 1477 PVC pipes and fittings for pressure applications

2017

No

PVC-U pipes for sewer, drain, waste and vent applications intended to be used where the pipeline is operating under gravity flow and the operating pressure is low, both plain and structured wall pipes.

AS/NZS 1260 PVC-U pipes and fittings for drain, waste and vent applications

2017

No

Pipes made of oriented unplasticised polyvinyl chloride (PVC-O).

AS/NZS 4441 Oriented PVC (PVC-O) pipes for pressure applications

2017

No

Pipes of PVC-M for the conveyance of water and wastewater under pressure.

AS/NZS 4765 Modified PVC (PVC-M) pipes for pressure applications

2017

No

Metric polybutylene (PB) pipe

Polybutylene pipe for heated and cold water applications.

AS 5082.1 Polybutylene (PB) plumbing pipe systems - Metric series - Metric polybutylene (PB) pipes for hot and cold water applications

2007

No

Glass-filament-reinforced thermosetting plastic (GRP) pipe

Glass-reinforced thermoplastics (GRP) pipes based on unsaturated polyester (UP) resin for pressure and non-pressure drainage and sewerage applications

AS 3571.1 Plastics piping systems - Glass-reinforced thermoplastics (GRP) systems based on unsaturated polyester (UP) resin - Pressure and non-pressure drainage and sewerage

2009

No

Glass-reinforced thermoplastics (GRP) systems based on unsaturated polyester (UP) resin for pressure and non-pressure water supply applications.

AS 3571.2 Plastics piping systems - Glass-reinforced thermoplastics (GRP) systems based on unsaturated polyester (UP) resin - Pressure and non-pressure water supply

2009

No
Plastic pipe with noise reductionNoise reduction pipes made of a compound of polypropylene and inert mineral additives for waste and drainage installations with intermittent operating temperatures up to 95°C.WMTS-508 Plastics piping systems for soil and waste discharge – with noise reduction characteristics2013No