List of Amendments - NCC 2016 - Volume One
/editions/2016/ncc-2016-volume-one/list-amendments/list-amendments-ncc-2016-volume-one
LIST OF AMENDMENTS - NCC 2016 - VOLUME ONE
This set of notes has been prepared by the Australian Building Codes Board to assist NCC users in identifying changes incorporated in the 2016 edition of Volume One.
The notes provide a description of…
Specification E2.2b Smoke Exhaust Systems
/editions/2016/ncc-2016-volume-one/section-e-services-and-equipment/specification-e22b-smoke-exhaust
1. Scope
This Specification describes the requirements for mechanical smoke exhaust systems.
Intent
To state that outlines the requirements for mechanical smoke exhaust systems.
Mechanical smoke exhaust systems
contains the requirements…
Section F Health And Amenity
/editions/2016/ncc-2016-volume-one/northern-territory/section-f-health-and-amenity
Part F5 Sound Transmission and Insulation
NT FP5.1
Floors separating sole-occupancy units must provide insulation against the transmission of airborne and impact generated sound sufficient to prevent illness or loss of amenity to the…
Specification C1.10 Fire hazard properties
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-c-fire-resistance/specification-c110-fire
1. Scope
This Specification sets out requirements in relation to the fire hazard properties of linings, materials and assemblies in Class 2 to 9 buildings as set out in Table 1.
Intent
To set out the scope of Specification C1.10.
It should…
Specification E2.2b Smoke exhaust systems
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-e-services-and-equipment/specification-e22b
1. Scope
This Specification describes the requirements for mechanical smoke exhaust systems.
Intent
To state that Specification E2.2b outlines the requirements for mechanical smoke exhaust systems.
Mechanical smoke exhaust systems…
Specification F5.2 Sound insulation for building elements
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-f-health-and-amenity/specification-f52
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of
construction.
(b)
Wall systems listed in…
Specification C1.10 Fire hazard properties
/editions/2019/ncc-2019-volume-one/section-c-fire-resistance/specification-c110-fire-hazard
1. Scope
This Specification sets out requirements in relation to the fire hazard properties of linings, materials and assemblies in Class 2 to 9 buildings as set out in Table 1.
Intent
To set out the scope of Specification C1.10.
It should…
Specification E2.2b Smoke exhaust systems
/editions/2019/ncc-2019-volume-one/section-e-services-and-equipment/specification-e22b-smoke-exhaust
1. Scope
This Specification describes the requirements for mechanical smoke exhaust systems.
Intent
To state that Specification E2.2b outlines the requirements for mechanical smoke exhaust systems.
Mechanical smoke exhaust systems…
Specification F5.2 Sound insulation for building elements
/editions/2019/ncc-2019-volume-one/section-f-health-and-amenity/specification-f52-sound-insulation
1. Scope
(a)
This Specification lists the weighted sound reduction index Rw for some common forms of construction.
(b)
Wall systems listed in Table 2 having a minimum 20 mm cavity between 2 separate leaves, with—
(i)
for masonry…
Specification E2.2b Smoke Exhaust Systems
/editions/2016-a1/ncc-2016-volume-one/section-e-services-and-equipment/specification-e22b-smoke
1. Scope
This Specification describes the requirements for mechanical smoke exhaust systems.
Intent
To state that outlines the requirements for mechanical smoke exhaust systems.
Mechanical smoke exhaust systems
contains the requirements…
Section F Health And Amenity
/editions/2016-a1/ncc-2016-volume-one/northern-territory/section-f-health-and-amenity
Part F5 Sound Transmission and Insulation
NT FP5.1
Floors separating sole-occupancy units must provide insulation against the transmission of airborne and impact generated sound sufficient to prevent illness or loss of amenity to the…
Part 3.5.1 Roof Cladding
/editions/2016/ncc-2016-volume-two/part-35-roof-and-wall-cladding/part-351-roof-cladding
Appropriate Performance Requirements
Appropriate Performance Requirements
Where an alternative roof cladding is proposed as a Performance Solution to that described in Part 3.5.1, that proposal must comply with—
; and
; and
the…
Part 3.5.1 Roof Cladding
/editions/2016-a1/ncc-2016-volume-two/part-35-roof-and-wall-cladding/part-351-roof-cladding
Appropriate Performance Requirements
Appropriate Performance Requirements
Where an alternative roof cladding is proposed as a Performance Solution to that described in Part 3.5.1, that proposal must comply with—
; and
; and
the…
Part C2 Compartmentation and Separation
/editions/2016/ncc-2016-volume-one/section-c-fire-resistance/part-c2-compartmentation-and-separation
C2.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements to are satisfied by complying with—
(i)
C1.1 to C1.13, C2.1 to C2.14andC3.1toC3.17; and
(ii)
in a building containing an…
Part C2 Compartmentation and Separation
/editions/2016-a1/ncc-2016-volume-one/section-c-fire-resistance/part-c2-compartmentation-and
C2.0 Deemed-to-Satisfy Provisions
(a)
Where a Deemed-to-Satisfy Solution is proposed, Performance Requirements to are satisfied by complying with—
(i)
C1.1 to C1.14, C2.1 to C2.14andC3.1toC3.17; and
(ii)
in a building containing an…
Specification C1.10 Fire Hazard Properties
/editions/2016/ncc-2016-volume-one/section-c-fire-resistance/specification-c110-fire-hazard
1. Scope
This Specification sets out requirements in relation to the fire hazard properties of linings, materials and assemblies in Class 2 to 9 buildings as set out in Table 1.
Intent
To set out the scope of .
It should be noted that…
Specification E1.5 Fire sprinkler systems
/editions/2019-a1/ncc-2019-volume-one-amendment-1/section-e-services-and-equipment/specification-e15
1. Scope
This Specification sets out requirements for the design and installation of fire sprinkler systems.
Intent
To state that Specification E1.5 gives the design and installation details for sprinkler systems required by the Deemed-to-…
Specification E1.5 Fire sprinkler systems
/editions/2019/ncc-2019-volume-one/section-e-services-and-equipment/specification-e15-fire-sprinkler
1. Scope
This Specification sets out requirements for the design and installation of fire sprinkler systems.
Intent
To state that Specification E1.5 gives the design and installation details for sprinkler systems required by the Deemed-to-…
Section F Health and amenity
/editions/2019/ncc-2019-volume-one/northern-territory/section-f-health-and-amenity
Part F5 Sound transmission and insulation
NT FP5.1 Sound transmission through floors
Floors separating sole-occupancy units must provide insulation against the transmission of airborne and impact generated sound sufficient to prevent illness…
Specification C1.10 Fire Hazard Properties
/editions/2016-a1/ncc-2016-volume-one/section-c-fire-resistance/specification-c110-fire-hazard
1. Scope
This Specification sets out requirements in relation to the fire hazard properties of linings, materials and assemblies in Class 2 to 9 buildings as set out in Table 1.
Intent
To set out the scope of .
It should be noted that…