Delete clause C3P5 and insert VIC C3P5 as follows:
On-site wastewater management systems that facilitate on-site storage, treatment, disposal or re-use of wastewater must be designed, constructed, installed, replaced, repaired, altered and maintained—
with required treatment and storage capacity for the volume and make up of waste and frequency of discharge for disposal; and
with required size, strength and rigidity for the nature, flow rates, volume of wastes and/or waste products which must be processed; and
using materials which are impervious both to the waste for which disposal is required and to water; and
to avoid the likelihood of surface water and stormwater entering the system; and
in accordance with the requirements and agreement of the relevant authority having jurisdiction.
avoid the likelihood of damage from superimposed loads or ground movement; and
avoid the likelihood off effluent and foul air and gasses entering the building.
(3) The on-site wastewater management system and associated land application system continue to meet the above requirements throughout its serviceable life.