NCC 2022 Volume One - Building Code of Australia Class 2 to 9 buildings
Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c

Filter

Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c

G1

Part G1 Minor structures and components

Part G1 Minor structures and components

VIC G1P2 Swimming pool access and water recirculation systems2019: VIC GP1.2

Delete clause G1P2 and insert VIC G1P2 as follows:

(1) A barrier must be provided to a swimming pool and must—

  1. be continuous for the full extent of the hazard; and
  2. be of a strength and rigidity to withstand the foreseeable impact of people; and
  3. restrict the access of young children to the pool and the immediate pool surrounds; and
  4. have any gates and doors fitted with latching devices not readily operated by young children, and constructed to automatically close and latch.

(2) A swimming pool water recirculation system must incorporate safety measures to avoid entrapment of, or injury to, a person.

Applications

  1. VIC G1P2(1) only applies to a swimming pool with a depth of water more than 300 mm associated with—
    1. a Class 2 or 3 building or Class 4 part of a building; or
    2. a children’s service.
  2. VIC G1P2(2) only applies to a swimming pool with a depth of water more than 300 mm.

VIC G1D2 Swimming pools2019: VIC G1.1

Delete clause G1D2 and insert VIC G1D2 as follows:

(1) A swimming pool associated with a children’s service, with a depth of water more than 300 mm, must have fencing or other barriers in accordance with AS 1926.1 and AS 1926.2.

(2) A swimming pool with a depth of water more than 300 mm and which is associated with a Class 2 or 3 building or Class 4 part of a building, must have suitable barriers to restrict access by young children to the immediate pool surrounds in accordance with AS 1926.1 and AS 1926.2.

(3) A water recirculation system in a swimming pool with a depth of water more than 300 mm must comply with AS 1926.3.