NCC 2022 Volume One - Building Code of Australia Class 2 to 9 buildings
Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c

Filter

Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c

I1

Part I1 Class 9b buildings

Part I1 Class 9b buildings

NSW I1D1 Application of Part2019: NSW H1.1

Delete clause I1D1 and insert NSW I1D1 as follows:

(1) For a Class 9b building or part of a building that is not an entertainment venue

  1. the Deemed-to-Satisfy Provisions of Part I1 apply to every enclosed Class 9b building or part of a building which—
    1. is a school assembly, church or community hall with a stage and any backstage area with a total floor area of more than 300 m2; or
    2. otherwise, has a stage and any backstage area with a total floor area of more than 200 m2; or
    3. has a stage with an associated rigging loft; and
  2. notwithstanding (1)(a)—
    1. I1D4 applies to every open or enclosed Class 9b building; and
    2. I1D7 applies to every enclosed Class 9b building.

(2) For a Class 9b building that is an entertainment venue, NSW Part I4 applies in replacement of Part I1.