NCC 2022 Volume One - Building Code of Australia Class 2 to 9 buildings
Search the National Construction Code editions
Filter
C2
Part C2 Fire resistance and stability
Part C2 Fire resistance and stability
NSW C2D11 Fire hazard properties2019: C1.10 and NSW C1.10
Delete clause C2D11 and insert NSW C2D11 as follows:
(1) The fire hazard properties of the following internal linings, materials and assemblies within a Class 2 to 9 building must comply with Specification 7:
Floor linings and floor coverings.
Wall linings and ceiling linings.
Air-handling ductwork.
Lift cars.
In Class 9b buildings used as—
an entertainment venue, a material used to cover closed back upholstered seats; and
(2) Paint or fire-retardant coatings must not be used in order to make a material comply with a requiredfire hazard property, except in respect of a material referred to in NSW Specification 7, NSW Table S7C7 and to which Notes 4 and 5 are applicable.
(3) The requirements of (1) do not apply to a material or assembly if it is—
plaster, cement render, concrete, terrazzo, ceramic tile or the like; or
timber treads, risers, landings and associated supporting framework installed in accordance with D3D30 where the Spread-of-Flame Index and the Smoke-Developed Index of the timber does not exceed 9 and 8 respectively; or
any other material that does not significantly increase the hazards of fire.