Insert TAS subclause A5G4(7) in clause A5G4 as follows:
(7) A product used in roof plumbing, heating ventilation and air-conditioning or on-site liquid trade waste are deemed fit to be for their intended purpose if it has evidence of suitability in the form of—
-
WaterMark Licence issued in accordance with the WaterMark Certification Scheme; or
- a current certificate issued by a certification body stating that the properties and performance of a product meet the requirements of the NCC Volume Three; or
- authorisation from the Director of Building Control.
Insert TAS subclause A5G4(8) in clause A5G4 as follows:
(8) A product used in On-site wastewater management systems are deemed to be fit for their intended purpose if it has evidence of suitability in the form of—
- an On-site wastewater management system used in a plumbing installation must be issued with a Certificate of Accreditation in accordance with the AS 1546 series of Standards; or
- a current certificate issued by a JAS-ANZ accredited certification body stating that the properties and performance of a product meets the requirement of NCC Volume Three; and
- accreditation from the Director of Building Control.
Insert TAS subclause A5G4(9) in clause A5G4 as follows:
(9) A holding tank or collection well for use in a plumbing or drainage installation may be verified as meeting the Performance Requirements of the Director of Building Control if complies with AS/NZS 1546.1.
Insert TAS subclause A5G4(10) in clause A5G4 as follows:
(10) Under the Tasmanian Building Act, the Director of Building Control may accredit an On-site wastewater management system. On-site wastewater management systems larger than that covered by the Australian Standards AS/NZS 1546 Series are exempt from accreditation and a Performance Solution is required.
Products accredited by the Director of Building Control are published in a list available at www.cbos.tas.gov.au.