Delete subclause D4D2(4) and insert SA D4D2(4) as follows:
(4) For a Class 2 building, access requirements are as follows:
- Common areas:
- From a pedestrian entrance required to be accessible to at least 1 floor containing sole-occupancy units and to the entrance doorway of each sole-occupancy unit located on that level.
- To and within not less than 1 of each type of room or space for use in common by the residents, including a cooking facility, sauna, gymnasium, swimming pool, common laundry, games room, individual shop, eating area, or the like.
- Where a ramp complying with AS 1428.1 or a passenger lift is installed—
- to the entrance doorway of each sole-occupancy unit; and
- to and within rooms or spaces for use in common by the residents.
- The requirements of (iii) only apply where the space referred to in (iii)(A) or (iii)(B) is located on the levels served by the lift or ramp.
- In developments consisting of 20 or more residential sole-occupancy units — to and within one residential sole-occupancy unit or 5% of the total number of residential sole-occupancy units provided, whichever is the greater, must be accessible.