Delete clause G1D2 and insert NSW G1D2 as follows:
(1) NSW G1D2(2) applies to the technical construction requirements for barriers to restrict access to swimming pools, subject to—
- out-of-ground pool walls and the walls of above ground pools, including inflatable pools, not being considered to be effective barriers; and
- the reference in clause 2.3.1 of AS 1926.1 to a barrier within a property including a boundary barrier.
(2) A swimming pool with a depth of water more than 300 mm and which is associated with a Class 2 or 3 building or Class 4 part of a building, must have suitable barriers to restrict access by young children to the immediate pool surrounds in accordance with—
- AS 1926.1 and AS 1926.2; or
- if the swimming pool is a spa pool—
- the requirements of (a); or
- clause 9 of the Swimming Pools Regulation 2018.
(3) A water recirculation system in a swimming pool with a depth of water more than 300 mm must comply with AS 1926.3.
Notes