NCC 2022 Volume One - Building Code of Australia Class 2 to 9 buildings
Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c

Filter

Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c

G1

Part G1 Minor structures and components

Part G1 Minor structures and components

NSW G1P2 Swimming pool access and water recirculation systems2019: NSW GP1.2

Delete clause G1P2 and insert NSW G1P2 as follows:

(1) A barrier must be provided to a swimming pool and must—

  1. be continuous for the full extent of the hazard; and
  2. be of a strength and rigidity to withstand the foreseeable impact of people; and
  3. restrict the access of young children to the pool and the immediate pool surrounds; and
  4. have any gates and doors fitted with latching devices not readily operated by young children, and constructed to automatically close and latch.

(2) A swimming pool water recirculation system must incorporate safety measures to avoid entrapment of, or injury to, a person.

Applications

  1. NSW G1P2(1) only applies to a swimming pool with a depth of water more than 300 mm, in conjunction with the Swimming Pools Act 1992 and the Swimming Pools Regulation 2018.
  2. NSW G1P2(2) only applies to a swimming pool with a depth of water more than 300 mm.

NSW G1D2 Swimming pools2019: NSW G1.1

Delete clause G1D2 and insert NSW G1D2 as follows:

(1) NSW G1D2(2) applies to the technical construction requirements for barriers to restrict access to swimming pools, subject to—

  1. out-of-ground pool walls and the walls of above ground pools, including inflatable pools, not being considered to be effective barriers; and
  2. the reference in clause 2.3.1 of AS 1926.1 to a barrier within a property including a boundary barrier.

(2) A swimming pool with a depth of water more than 300 mm and which is associated with a Class 2 or 3 building or Class 4 part of a building, must have suitable barriers to restrict access by young children to the immediate pool surrounds in accordance with—

  1. AS 1926.1 and AS 1926.2; or
  2. if the swimming pool is a spa pool
    1. the requirements of (a); or
    2. clause 9 of the Swimming Pools Regulation 2018.

(3) A water recirculation system in a swimming pool with a depth of water more than 300 mm must comply with AS 1926.3.

Notes

The Swimming Pools Act 1992 and the Swimming Pools Regulation 2018, applicable to swimming pool with a depth of water of more than 300 mm, regulate the circumstances in which a barrier is required and prevail in the case of any inconsistency.

NSW G1D5 Provision for cleaning windows2019: NSW G1.101

Insert NSW clause G1D5 in clause G1D5 as follows:

(1) A building must provide for a safe manner of cleaning any windows located 3 or more storeys above ground level.

(2) A building satisfies (1) where—

  1. the windows can be cleaned wholly from within the building; or
  2. provision is made for the cleaning of the windows by a method complying with the Work Health and Safety Act 2011 and regulations made under that Act.