F4

Part F4 Sanitary and other facilities

Part F4 Sanitary and other facilities

NSW F4P6 Microbial control for water systems

This clause been deliberately left blank
F4P6 does not apply in NSW as the installation of hot water, warm water and cooling water systems (and their operation and maintenance) is regulated in the Public Health Regulation 2012, under the Public Health Act 2010.
Table F4D4d Sanitary facilities in Class 6 buildings – restaurants, cafes, bars
User group Facility type Design occupancy Number
Male patrons Closet pans 1 - 100 1
101 - 300 2
>300 Add 1 per 200
Urinals 1 - 50 1
51 - 100 2
101 - 150 3
151 - 200 4
201 - 250 5
>250 Add 1 per 100
Washbasins 1 - 50 1
51 - 200 2
>200 Add 1 per 200
Female patrons Closet pans 1 - 25 1
26 - 50 2
51 - 100 3
101 - 150 4
151 - 200 5
201 - 250 6
>250 Add 1 per 100
Washbasins 1 - 50 1
51 - 150 2
>150 Add 1 per 200
Table Notes

Sanitary facilities need not be provided for patrons if the total number of persons accommodated in the building is not more than 20.

Delete table (F4D4d) and insert NSW table (F4D4d) as follows:
NSW Table F4D4d: Sanitary facilities in Class 6 buildings – restaurants, cafes, bars
User group Facility type Design occupancy Number
Male patrons Closet pans 1 - 100 1
101 - 300 2
>300 Add 1 per 200
Urinals 1 - 50 1
51 - 100 2
101 - 150 3
151 - 200 4
201 - 250 5
>250 Add 1 per 100
Washbasins 1 - 50 1
51 - 200 2
>200 Add 1 per 200
Female patrons Closet pans 1 - 25 1
26 - 50 2
51 - 100 3
101 - 150 4
151 - 200 5
201 - 250 6
>250 Add 1 per 100
Washbasins 1 - 50 1
51 - 150 2
>150 Add 1 per 200
Note
  1. Sanitary facilities need not be provided for patrons if the total number of persons accommodated in the building is not more than 20.
  2. Sanitary facilities need not be provided for patrons in a small live music or arts venue that is not a licensed premises.

NSW F4D10 Microbial (legionella) control

This clause been deliberately left blank
F4D10 does not apply in NSW as the installation of hot water, warm water and cooling water systems (and their operation and maintenance) is regulated in the Public Health Regulation 2012, under the Public Health Act 2010.