NSW Part I6 Drive-in theatres
Deemed-to-Satisfy Provisions
NCC Blurbs
This Part applies to drive-in theatres.
NCC SPTC Current
Application of Part
NCC ID
_b7cfa03e-2c2d-449c-98ba-eb0e6b53777b
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Speaker standards must—
- be placed at a minimum of 5.5 m centres in a line along each parking ramp; and
- be capable of being illuminated throughout any performance so as to be easily distinguishable at all times.
NCC SPTC Current
Speaker standards
NCC ID
_c2378627-53e4-48b7-a969-06fada0fc51c
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Lines of speaker standards along parking ramps must be placed at a distance of not less than 12.2 m apart.
NCC Title
Lines of speaker standards
NCC SPTC Current
Lines of speaker standards
NCC ID
_fe4d5e1a-ffde-442d-b970-bbd4ad1e402e
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
The following electrical services must be installed underground—
- the supply authority’s conductors within the site and the consumer’s mains, unless otherwise approved; and
- electrical wiring external to any building on the site; and
- all wiring to the speaker standards.
NCC SPTC Current
Electrical services
NCC ID
_1935439d-0cc1-49cf-90f7-501845640481
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Each public vehicular entrance to or exit from the drive-in theatre must be capable of being fully illuminated by flood lights that are so placed and so focussed as not to interfere with the vision of the driver of any motor vehicle.
NCC SPTC Current
Vehicular entrances
NCC ID
_10fb6fc4-0760-4ae2-8fe4-a8648f32f980
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
(1) Driveways — Entrance and exit driveways, and the perimeter of the holding area, must be capable of being continuously illuminated by lamps capable of producing a minimum illumination of 0.5 lux at ground level.
(2) Ramp areas — The whole of the ramp area of a drive-in theatre must be capable of being floodlit by means of area flood lights to an illumination of at least 10 lux.
NCC SPTC Current
Lighting
NCC ID
_de284f36-aedd-487d-928d-7b409fcd4aa0
Building Classes
1a,1b,10a,10b,10c