NCC 2022 Volume One - Building Code of Australia Class 2 to 9 buildings
Search the National Construction Code editions
Filter
I4
TAS Part I4 Food premises
TAS Part I4 Food premises
Introduction to this Part
This Part contains additional requirements for food premises.
Objectives
NCC Blurbs
The objective of this Part is to facilitate the safe manufacture, preparation, storage and packing of food for sale for human consumption.
NCC Title
Objective
NCC State
TAS
NCC SPTC Current
Objective
NCC ID
_01ae33c5-dab7-4e00-bb2d-830fc0f88101
Building Classes
1a,1b,10a,10b,10c
Functional Statements
NCC Blurbs
Each building or part of a building constructed as a food premise must be able to be used in such a manner that minimises opportunities for food contamination.
NCC Title
Food premises
NCC State
TAS
NCC SPTC Current
Food premises
NCC ID
_879d5bc6-de18-40f6-8322-4c38c0935a67
Building Classes
1a,1b,10a,10b,10c
Performance Requirements
NCC Blurbs
(1) TAS I4P2 to TAS I4P13 applies to any premises where food intended for human consumption is manufactured, processed, prepared, packed, stored or sold and to which the following apply—
premises for boning, curing, canning, pre-packing or other similar processes of preparation of meat for sale; and
retail meat premises; and
eating houses and tea shops; and
fish shops; and
kitchens in eating houses, restaurants, guest houses, motels and hotels; and
rooms for processing, manufacturing, packing, etc. of fruit and vegetables, dairy products, ice blocks, ices, meat-for-sale, or other fish; and
primary produce business premises regulated by or under a Food Safety Scheme made under the Primary Produce Safety Act; and
take-away-food stores; and
breweries and wineries.
(3) In TAS I4P2 to TAS I4P13, words and meanings as defined in the Food Act 2003, Food Standards Code and Liquor Licensing Act 1990, Dairy Industry Act 1994 and Primary Produce Safety Act 2011 apply.
domestic dwellings classified as Class 1 buildings; or
boarding houses or the like classified as Class 1 buildings; or
tents, buildings or other structures used temporarily for serving meats to the public at any fair, show, race meeting or other public sports, games or amusements; or
live shellfish premises where live shellfish are being packed or handled for transport or transferral to shellfish processing premises; or
premises that only sell pre-packaged food that is not potentially hazardous.
NCC Title
Application of Part
NCC State
TAS
NCC SPTC Current
Application of Part
NCC ID
_01c49357-917f-4dc6-bd0c-638f5b648226
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
The design and construction of food premises must—
be appropriate for the activities for which the premises are used; and
provide adequate space for the activities to be conducted on the food premises and for the fixtures, fittings and equipment used for those activities; and
permit the food premises to be effectively cleaned and, if necessary, sanitised; and
to the extent that is practicable—
exclude dirt, dust, odours, fumes, smoke and other contaminants; and
not permit the entry of pests; and
not provide harbourage for pests; and
provide that the food premises is able to be used in such a manner that minimises opportunities for food contamination.
NCC Title
Design and construction
NCC State
TAS
NCC SPTC Current
Design and construction
NCC ID
_d964f906-e0d9-4623-a3cd-7f53950ccbcc
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
(1) Food premises must have an adequate supply of water if water is to be used at the food premises for any of the activities conducted on the food premises.
(2) A food premises must use potable water for all activities that use water that are conducted on the food premises.
Limitations
If a food business demonstrates that the use of non-potable water for a purpose will not adversely affect the safety of the food handled by the food business TAS I4P3(2) does not apply.
NCC Title
Water supply
NCC State
TAS
NCC SPTC Current
Water supply
NCC ID
_d2a423d3-c166-425b-ac6e-8c5a55d367c5
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Food premises must have a sewage and waste water disposal system that—
will effectively dispose of all sewage and waste water; and
is constructed and located so that there is no likelihood of the sewage and waste water polluting the water supply or contaminating food.
NCC Title
Sewage and waste water disposal
NCC State
TAS
NCC SPTC Current
Sewage and waste water disposal
NCC ID
_7f7735ef-e6d0-41f7-a6bb-e26a9a9de447
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Food premises must have facilities for the storage of garbage and recyclable matter that—
adequately contain the volume and type of garbage and recyclable matter on the food premises; and
enclose the garbage or recyclable matter, if this is necessary to keep pests and animals away from it; and
are designed and constructed so that they may be effectively cleaned.
NCC Title
Storage of garbage and recyclables
NCC State
TAS
NCC SPTC Current
Storage of garbage and recyclables
NCC ID
_6b4ef2ad-9bdc-455b-bb91-7d0c88302717
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Food premises must have sufficient natural or mechanical ventilation to remove fumes, smoke and vapours from the food premises.
NCC Title
Ventilation
NCC State
TAS
NCC SPTC Current
Ventilation
NCC ID
_41d82e3c-6c95-4332-8c85-13d1b4c8ce31
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Food premises must have lighting systems that provide sufficient natural or artificial light for the activities conducted on the food premises.
NCC Title
Lighting
NCC State
TAS
NCC SPTC Current
Lighting
NCC ID
_651c3900-81ea-4d75-be72-2532f67b1085
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
(1) Floors must be designed and constructed in a way that is appropriate for the activities conducted on the food premises.
(2) Floors must—
be able to be effectively cleaned; and
be unable to absorb grease, food particles or water; and
be laid so that there is no ponding of water; and
to the extent that is practicable, be unable to provide harbourage for pests.
Applications
The requirements for floors apply to the floors of all areas used for food handling, cleaning, sanitising and personal hygiene except the following areas—
dining areas; and
drinking areas; and
other areas to which members of the public usually have access.
Exemptions
The following floors do not have to comply with TAS I4P8(2)—
floors of temporary food premises, including ground surfaces, that are unlikely to pose any risk of contamination of food handled on the food premises; and
floors of food premises that are unlikely to pose any risk of contamination of food handled on the food premises provided the food business has obtained approval for their use.
NCC Title
Floors
NCC State
TAS
NCC SPTC Current
Floors
NCC ID
_105e17f7-1c03-441a-b239-584e33f58d2e
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Walls and ceilings—
must be designed and constructed in a way that is appropriate for the activities conducted on the food premises; and
must be provided where they are necessary to protect food from contamination; and
provided in accordance with (b) must be—
sealed to prevent the entry of dirt, dust and pests; and
unable to absorb grease, food particles or water; and
able to be easily and effectively cleaned; and
must—
be able to be effectively cleaned; and
to the extent that is practicable, be unable to provide harbourage for pests.
Applications
The requirements for walls and ceilings apply to the walls and ceilings of all areas used for food handling, cleaning, sanitising and personal hygiene except for the following areas—
dining areas; and
drinking areas; and
other areas to which members of the public usually have access.
NCC Title
Walls and ceilings
NCC State
TAS
NCC SPTC Current
Walls and ceilings
NCC ID
_b3121667-ff79-4442-b0a6-2be3b0f0dc86
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
(1) Food premises must have hand washing facilities that are located where they can be easily accessed by food handlers—
within areas where food handlers work if their hands are likely to be a source of contamination of food; and
if there are toilets on the food premises — immediately adjacent to the toilets or toilet cubicles.
(2) Hand washing facilities must be—
permanent fixtures; and
provided with a supply of warm running potable water; and
of a size that allows easy and effective hand washing; and
clearly designated for the sole purpose of washing hands, arms and face.
NCC Title
Hand washing facilities
NCC State
TAS
NCC SPTC Current
Hand washing facilities
NCC ID
_a1abcdda-f041-42b7-b71e-cf891690800c
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Fixtures, fittings and equipment must—
be adequate for the production of wholesome food; and
be fit for their intended use; and
be designed, constructed, located and installed, and equipment must be located and, if necessary, installed, so that—
there is no likelihood that they will cause food contamination; and
they are able to be easily and effectively cleaned; and
adjacent floors, walls, ceilings and other surfaces are able to be easily and effectively cleaned; and
to the extent that is practicable, they do not provide harbourage for pests; and
have food contact surfaces—
able to be easily and effectively cleaned and, if necessary, sanitised if there is a likelihood that they will cause food contamination; and
unable to absorb grease, food particles and water if there is a likelihood that they will cause food contamination; and
made of a material that will not contaminate food.
NCC Title
Fixtures, fittings and equipment
NCC State
TAS
NCC SPTC Current
Fixtures, fittings and equipment
NCC ID
_9186babe-fa84-4f5a-b3f7-c6673c333c12
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Food premises must have adequate storage facilities—
for the storage of items that are likely to be the source of contamination of food, including chemicals, clothing and personal belongings; and
located where there is no likelihood of stored items contaminating food or food contact surfaces.
NCC Title
Storage facilities
NCC State
TAS
NCC SPTC Current
Storage facilities
NCC ID
_d103e10b-d401-40e7-b34d-95f376cde2ab
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
All refrigerated and cooling chambers must be constructed so that the stored products will not be contaminated.
NCC Title
Refrigerated and cooling chambers
NCC State
TAS
NCC SPTC Current
Refrigerated and cooling chambers
NCC ID
_757ba051-8c39-403a-b751-145a702509e7
Building Classes
1a,1b,10a,10b,10c
Deemed-to-Satisfy Provisions
NCC Blurbs
(1) This Part applies to any premises where food intended for human consumption is manufactured, processed or sold and to which the following apply—
Food Act 2003; or
Liquor Licensing Act 1990; or
Primary Produce Safety Act 2011; or
Dairy Industry Act 1994.
(2) This Part includes, but is not limited to—
bakehouses; and
bar service areas; and
premises for boning, curing, canning, mincing, pre-packing or other similar processes of preparation of meat for sale; and
retail meat premises; and
eating houses and tea shops; and
fish shops; and
kitchens in eating houses, restaurants, guest-houses, motels and hotels; and
rooms for processing, manufacturing, packing, etc. of fruit and vegetables, dairy products, ice blocks, ices, meat-for-sale or other fish; and
primary produce business premises regulated by or under a Food Safety Scheme made under the Primary Produce Safety Act 2011; and
take-away-food stores; and
breweries and wineries.
(3) This Part does not apply to—
boarding houses or the like classified as Class 1 buildings; or
tents, buildings or other structures used temporarily for serving meals to the public at any fair, show, race meeting or other public sports, games or amusements; or
live shellfish premises where live shellfish are being packed or handled for transport or transferral to shellfish processing premises; or
premises that only sell pre-packaged food that is not potentially hazardous.
(4) In this Part, words and meanings as defined in the Food Act 2003, Food Standards Code and Liquor Licensing Act 1990, Dairy Industry Act 1994 and Primary Produce Safety Act 2011 apply.
(4) The provision of a reticulated water supply from—
a regulated entity; or
a private water supply with on-site treatment,
which meets the Australian Drinking Water Guidelines, satisfies TAS I4P3(2).
Notes
‘Regulated entity’ has the same meaning as Water and Sewerage Industry Act 2008.
NCC Title
General requirements
NCC State
TAS
NCC SPTC Current
General requirements
NCC ID
_bdf9bfba-8b14-4fb6-9dc0-8ce668c13d3a
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Premises where customers are served outside the premises through an opening, that has an appliance for the elimination of flies and mechanical ventilation adequate to exhaust air through the opening at a rate of not less than 5 litres per second for each square metre of opening, satisfies TAS I4P2(d).
a grease trap, an overflow (relief) gully or an untrapped opening connected directly with a drain or sewer, is not installed in a room used for preparation, processing, packing or storing of food for sale; and
as far as is practicable, service pipes are concealed beneath the surface of walls, floors or ceilings, or are fixed clear of the wall, floor or ceiling, at such distance as to facilitate cleaning.
NCC Title
Drains and pipes
NCC State
TAS
NCC SPTC Current
Drains and pipes
NCC ID
_cfa7a9d9-c213-491e-a083-5a43d72ea231
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Where offensive material or trade waste is stored, a separate area or room which—
is paved and easily cleanable; and
is graded to drain to a suitable drainage system; and
(1) Floors, walls and ceilings constructed in accordance with Section 3 of AS 4674, satisfy TAS I4P8 and TAS I4P9.
(2) The wall and ceiling provisions of (1) do not apply to areas in which all food for sale is completely enclosed and otherwise protected from contamination by processing plants, other appliances or other means.
NCC Title
Floors, walls and ceilings
NCC State
TAS
NCC SPTC Current
Floors, walls and ceilings
NCC ID
_b911f434-8f09-4898-93a6-1a0af88098ef
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
(1) A room where food for sale is processed, manufactured, prepared, deposited, treated, stored or packed, that does not have direct communication with a room containing sanitary facilities, living quarters, laundry, bathroom or garage or a room where animals are housed, satisfies TAS I4P9(b).
(2) ‘Direct communication’ means a doorway, a window or other opening in a wall between a food preparation or storage area opening directly on to a room described in (1).
(3) Access between the areas referred to in (2) via another room, a hallway, or an airlock, satisfies TAS I4P9(b).
NCC Title
Separation of work place
NCC State
TAS
NCC SPTC Current
Separation of work place
NCC ID
_7a85664d-b191-4ebc-990b-95ab99fd8538
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
(1) Premises or places for preparation or storage of food for sale provided with not less than one washbasin complying with (2) within five metres of any activities where hands are likely to be a source of contamination of food, satisfies TAS I4P10.
(2) Each washbasin must—
have hot and cold water through a common outlet; and
have a capacity of at least 11 litres; and
provide not less than 250 mm between the spout and the bottom of the basin; and
be in a position that is not obstructed.
NCC Title
Washbasins
NCC State
TAS
NCC SPTC Current
Washbasins
NCC ID
_703692b5-e681-4500-9201-6d3e0c562bd3
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
(1) Where equipment and utensils are required to be manually cleaned and sanitised, or food preparation requires a sink, premises that are provided with a suitably sized double bowl sink for equipment washing and a separate suitably sized sink for food preparation of stainless steel supplied with—
hot and cold water; and
in integral drainer on at least one side or a third bowl,
(2) A sink installed adjacent to a wall or other vertical surface, that is fitted with an integral flashing to that wall or vertical surface to a height of not less than 150 mm, satisfies TAS I4P11.
(3) A sink provided with an integral surround not less than 150 mm wide except on sides with an integral flashing as in (2), satisfies TAS I4P11.
(4) A cleaner’s sink separated from food storage and handling areas provided for the emptying of cleaning water, satisfies TAS I4P11.
NCC Title
Sinks
NCC State
TAS
NCC SPTC Current
Sinks
NCC ID
_32245523-cf27-412d-802c-d0943f851964
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
(1) The provision of fixtures, fittings and equipment designed, constructed and installed in accordance with clause 4.2 and clause 4.3 of AS 4674 satisfies TAS I4P11.
(2) The provision of—
automatic equipment that uses water to sanitise utensils or other equipment and only operate for the purposes of sanitation when the water is at a temperature that will sanitise the utensils or equipment; or
Design, construction and installation of fixtures, fittings and equipment
NCC State
TAS
NCC SPTC Current
Design, construction and installation of fixtures, fittings and equipment
NCC ID
_cb7eb75e-7413-49ba-81a9-b7b532bef9e9
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
(1) Separate areas for the storage of fuel, cleaning compounds and general maintenance equipment provided so as to prevent contamination of the product in the event of a spillage of any other form of breakdown, satisfies TAS I4P12.
(2) A separate area for the storage of staff clothing and personal effects, satisfies TAS I4P12.
NCC Title
Storage of materials and equipment
NCC State
TAS
NCC SPTC Current
Storage of materials and equipment
NCC ID
_153715d7-b4fa-4ec6-a7dd-fee4c5afa189
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
An eating house provided with a dry-food store, satisfies TAS I4P12.
NCC Title
Food store
NCC State
TAS
NCC SPTC Current
Food store
NCC ID
_ea750d01-76a6-4456-8b50-a55e57aff440
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Premises used for the preparation or sale of red meat, other than those licensed under the Primary Produce Safety Act 2011, that comply with—
Premises designed and constructed in compliance with the Export Control (Milk and Dairy) Orders, satisfy the special requirements of this code for premises to be used for the manufacture of dairy produce.
NCC Title
Dairy produce
NCC State
TAS
NCC SPTC Current
Dairy produce
NCC ID
_ca4a59a2-0b24-40a2-92f0-b05251fd42be
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
The construction of a refrigerated chamber or cooling chamber installed in premises for storage of food complying with the requirements for that premises, satisfies TAS I4P13 where they have—
internal and external panels adhered directly to the insulated core material to form an integral wall section with tight fitting edges resistant to penetration by liquids; and
every joint caulked with a water-resistant, flexible sealer and finished in such a manner as to prevent migration of liquids into the core; and
every intersection of walls with floors and walls with walls coved with a radius not less than 25 mm; and
exposed slot-head screws or open-headed pop rivets filled with sealer; and
service pipes and conduits concealed in floors, walls or ceilings, if practicable, or fixed on brackets to provide clearances of not less than 25 mm between the pipe and a wall and 100 mm between the pipe and a floor; and
fittings not fixed over exposed pipes nor in a position to make difficult the cleaning of the pipe and surrounding area; and
rat proof construction, and any inaccessible spaces between the low temperature room and surrounding walls, ceilings and fixtures proof against rats an vermin; and
floor graded, as shown in Table TAS I4D18a, to drains located outside the chamber as near as practicable to the door opening; and
drainage from cooling units within the chamber constructed in accordance with Table TAS I4D18b, draining to a trapped outlet located outside the chamber.
Insert TAS table (I4D18a) I4D18 as follows:
TAS Table I4D18a: Floor drainage of refrigerated cooling chambers
Chiller type
Floor slope
Active chillers
Not less than 1:50
Other chambers
Not less than 1:100
Insert TAS table (I4D18b) I4D18 as follows:
TAS Table I4D18b: Drainage from cooling units within refrigerated chambers or cooling chambers
Cooling unit type
Drainage requirements
Wall-mounted
Drain water must be contained and removed by either a wall-mounted channel or a spoon drain located under the coil.
Floor-mounted
Drain water must be confined by kerbs, of a height not less than 150 mm, and directed to a trapped drain outlet.
Ceiling-mounted
Drain water must be confined by suitable insulated drip trays directly connected to the drainage system.