NCC 2022 Volume One - Building Code of Australia Class 2 to 9 buildings
Search the National Construction Code editions
I18
TAS Part I18 Temporary structuresTAS Part I18 Temporary structures
This Part contains additional requirements for temporary structures.
TAS I18P2 to TAS I18P16 only apply to a temporary structure that—
A temporary structure must, to the degree necessary, be capable of sustaining at an acceptable level of safety and serviceability the most adverse combination of loads and other actions to which it may reasonably be expected to be subjected.
The material used in a temporary structure must, to the degree necessary, be capable of resisting the spread of fire to limit the generation of smoke and heat, and any toxic gases likely to be produced.
Where a person could fall 1 m or more, due to a sudden change of level within or associated with a temporary structure, a barrier must to the degree necessary, be provided which must be—
A level of illumination for safe evacuation from a temporary structure in an emergency must be provided, to the degree necessary, appropriate to the—
To facilitate evacuation from a temporary structure suitable signs or other means of identification must, to the degree necessary—
Fire equipment must be installed in a temporary structure to the degree necessary, to allow the occupants to undertake initial attack on a fire appropriate to the—
Sanitary facilities for personal hygiene must be provided in a convenient location associated with a temporary structure, to the degree necessary, appropriate to the—
Electrical services must be installed to the degree necessary, to provide a level of safety appropriate to the environment and function or use of a temporary structure by the occupants.
Where provided for a temporary structure, a heating appliance and its associated components must be installed to the degree necessary—
A temporary structure of tiered seating must be designed and constructed to the degree necessary, to provide for the safety of occupants and orderly means of evacuation in an emergency.
A temporary structure must, to the degree necessary, be a safe and hazard free environment for the people using the structure.
This Part only applies to a temporary structure that—
Performance RequirementsTAS I18P1 to TAS I18P16 are satisfied by complying with the provisions of the ABCB Temporary Structures Standard, except for the following:
All electrical installations in a temporary structure must be installed in accordance with AS/NZS 3000.
The installation of a stove, heater or similar appliance in a temporary structure must as far as practicable comply with the following standards: