NCC 2022 Volume One - Building Code of Australia Class 2 to 9 buildings
Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c

Filter

Classification
Building class 1a Building class 1b Building class 2 Building class 3 Building class 4 Building class 5 Building class 6 Building class 7a Building class 7b Building class 8 Building class 9a Building class 9b Building class 9c Building class 10a Building class 10b Building class 10c

I7

TAS Part I7 Farm dairy premises

TAS Part I7 Farm dairy premises

Introduction to this Part

This Part contains additional requirements for farm dairy premises.

Deemed-to-Satisfy Provisions

NCC Blurbs

(1) This Part is applicable to every farm dairy as covered by the Dairy Industry Act 1994.

(2) Dairies must be constructed in such a manner that contamination of milk can be avoided.

NCC Title

Application of Part

NCC State
TAS
NCC SPTC Current
Application of Part
NCC Blurbs

(1) The walls (including the walls of a pit of a herringbone design milking shed) must be non-absorbent and easy to clean.

(2) The floor of a holding yard and a milking shed must be non-absorbent, easy to clean and free-draining.

(3) The lighting of a holding yard and a milking shed must be adequate for proper milking.

(4) The working space in a milking shed is to be sufficient to minimise the risk of contamination of milk during milking.

(5) Effluent from a holding yard and a milking shed is to be drained to a suitable point for disposal.

(6) The requirements of (1), (2) and (3) are satisfied if—

  1. the walls are constructed of well-compacted smooth finish concrete or other material sealed to be impervious to moisture; and
  2. the floors are constructed of well-compacted smooth finish concrete and are graded to a drain; and
  3. joints between wall sections and walls and walls and floors are sealed to prevent entry of water and pests; and
  4. artificial lighting is designed to comply with AS 1680.
NCC Title

Milking sheds and holding yards

NCC State
TAS
NCC SPTC Current
Milking sheds and holding yards
NCC Blurbs

(1) A Milk Receiving Area and Milk Storage Room must—

  1. have internal surfaces that are smooth, non-absorbent, free-draining and easy to clean; and
  2. be constructed so as to prevent the entry of dust, insects, pests, birds and animals; and
  3. have adequate artificial lighting that—
    1. is located to provide a clear view of the milk for grading and measuring purposes; and
    2. the lights over a bulk vat are to be protected to prevent glass entering the vat if the light is broken; and
    3. have switches appropriately located in milk collection areas; and
  4. have adequate ventilation to aid the drying of floors and walls between milkings.

(2) The requirements of (1) are satisfied if—

  1. the floors are constructed of well-compacted, smooth finish concrete and graded to a drain; and
  2. the internal surfaces are smooth, sealed and washable; and
  3. joists between wall sections and walls and floors are sealed to prevent entry of water and pests; and
  4. artificial lighting is designed to comply with AS 1680; and
  5. all openings are fitted with doors, windows or screens; and
  6. ventilation is provided in accordance with F6D6.
NCC Title

Milk receiving area and milk storage room

NCC State
TAS
NCC SPTC Current
Milk receiving area and milk storage room
NCC Blurbs

An adequate and suitable supply of water must be available for plant sanitation, teat washing, milk cooling and vat rinsing.

NCC Title

Water supply

NCC State
TAS
NCC SPTC Current
Water supply