NCC 2022 Volume One - Building Code of Australia Class 2 to 9 buildings
Search the National Construction Code editions
Filter
I11
TAS Part I11 Foundries
TAS Part I11 Foundries
Introduction to this Part
This Part contains additional requirements for foundries.
Deemed-to-Satisfy Provisions
TAS I11D1 Application of Part
2019: TAS H113.1
NCC Blurbs
(1) This Part is applicable to every building or premises on which foundry operations are undertaken.
(2) Foundries must provide for the comfort and safety of workers on the premises.
NCC Title
Application of Part
NCC State
TAS
NCC SPTC Current
Application of Part
NCC ID
_ca6bf620-88fe-42b3-ad61-74e86ef63a47
Building Classes
1a,1b,10a,10b,10c
TAS I11D2 General
2019: TAS H113.2
NCC Blurbs
(1) Every floor in a foundry must be level and, in places other than where molten metal is poured, must be composed or similar material or wooden blocks.
(2) Every part of a foundry must be not less than 4.2 m high—
where a ceiling is provided, measured from the floor to the ceiling; or
where a ceiling is not provided, measured from the floor to the lowest part of the roof.
NCC Title
General
NCC State
TAS
NCC SPTC Current
General
NCC ID
_faa38db7-e9ab-4155-8560-a5c09497eab6
Building Classes
1a,1b,10a,10b,10c
TAS I11D3 Cupola charging platform
2019: TAS H113.3
NCC Blurbs
(1) The floors of cupola charging platforms must be—
of heavy timber or non-slip steel plate; and
securely fixed in position; and
level.
(2) All parts of the cupola charging platform must be covered by a roof not less than 3 m above the platform.
(3) A cupola charging platform must have—
a wall, not less than 1 m high, measured from the floor of the platform, constructed to surround the platform; and
the side between the top of the wall and the roof suitably waterproofed an ventilated.
(4) A properly constructed access stair or ramp must be provide to give access to every cupola charging platform and must comply with AS 1657.
NCC Title
Cupola charging platform
NCC State
TAS
NCC SPTC Current
Cupola charging platform
NCC ID
_75a404a0-4b99-4ace-ac0a-babe8b1fe435
Building Classes
1a,1b,10a,10b,10c
TAS I11D4 Deep moulds and pits
2019: TAS H113.4
NCC Blurbs
Deep moulds or pits, for permanent use—
must be lined with bricks, concrete, or other suitable material in such a manner as to provide adequate reinforcement and to keep the pit or mould in a dry condition; and
must be securely fenced by means of a wall of adequate construction, railings or chains and stanchions raised, in each case, to a height not less than 1 m above the surface of the surrounding floor.
NCC Title
Deep moulds and pits
NCC State
TAS
NCC SPTC Current
Deep moulds and pits
NCC ID
_aa30e449-6625-4e7e-910b-89f926bf3ab3
Building Classes
1a,1b,10a,10b,10c
TAS I11D5 Pot furnaces
2019: TAS H113.5
NCC Blurbs
Where pot furnaces are below ground level, the pit must be covered by a substantial grating at the point at which metal is removed from the furnace, and must at all other times be securely fenced as in TAS I11D4(b)