SA Part G8 Access for maintenance
Introduction to this Part
This Part sets out additional requirements for access for maintenance.
NCC Blurbs
The Objectives of this Part are—
- to safeguard people from injury while cleaning windows; and
- to safeguard people from injury or illness resulting from the creation of hazardous spaces between buildings.
NCC SPTC Current
Objective
NCC ID
_44ae00a6-a07a-47fd-b835-5010995ba27e
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
A building is to provide people with safe conditions for carrying out window cleaning operations.
NCC SPTC Current
Window cleaning
NCC ID
_ef8fa1ed-66c5-48cb-9f5c-097e9e9003e6
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
The space between buildings must not allow hazardous conditions to arise due to accumulation of rubbish that cannot readily be removed.
NCC SPTC Current
Hazardous conditions
NCC ID
_c03c26b9-78ea-444b-b8b7-f924c23c0d4e
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Where any part of a window in a building is more than 5.5 m above ground level, provision must be made for safe access to the external surface of the window for minor maintenance and cleaning.
NCC SPTC Current
Window cleaning
NCC ID
_57753e6b-bbba-4180-a0ae-e7d2c732b61e
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
The space between buildings must be sufficient to allow access for inspection and maintenance, to avoid hazardous conditions arising due to accumulation of rubbish that could—
- bridge termite barriers; or
- harbour vermin; or
- create a fire hazard.
NCC SPTC Current
Hazardous conditions
NCC ID
_5a8e098d-47d3-44fb-8dd0-8f3f47b987c8
Building Classes
1a,1b,10a,10b,10c
Deemed-to-Satisfy Provisions
NCC Title
Deemed-to-Satisfy Provisions
NCC SPTC Current
Deemed-to-Satisfy Provisions
NCC ID
_36707c3a-a9e7-4686-be95-f8fe0fb3ada4
Building Classes
1a,1b,10a,10b,10c
NCC SPTC Current
Application of Part
NCC ID
_b219f268-5087-4568-9f17-0c6a4c50da92
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
(1) Where any part of a window in a building is more than 5.5 m above ground level, access to the external surface of the window for minor maintenance and cleaning must be provided.
(2) Any of the following methods are acceptable—
- by means of a movable gantry; or
- by means of reversible pivoting sashes, each of which has catches that secure the mesh in either the normal or reversed position and give visual indication that the window is secure, provided that where a window sill is less than 900 mm above floor level, safety anchorages are provided; or
- by means of safety harness, having all anchorages—
- designed and installed in accordance with AS/NZS 1891.4; and
- constructed of approved corrosion resistant material; or
- by means of opening sashes, in which the maximum reach to the farthest part of the window must not exceed 500 mm upwards or 1 m sideways or downwards and provided that where the window sill is less than 900 mm above floor level, safety anchorages are provided.
NCC Title
Access for window cleaning
NCC SPTC Current
Access for window cleaning
NCC ID
_8d8aac3b-1628-4b1d-938f-632439961ecb
Building Classes
1a,1b,10a,10b,10c
NCC Blurbs
Every part of an external wall of a building must be not less than 600 mm from—
- the external wall of any other building on the same allotment, unless the two buildings are abutting; or
- any boundary of the allotment, unless that wall is on or abutting the boundary,
unless the space between external columns is not infilled.
NCC Title
Access for inspection and maintenance between buildings
NCC SPTC Current
Access for inspection and maintenance between buildings
NCC ID
_fb030a71-d407-4c31-9de3-fb0bed7027d6
Building Classes
1a,1b,10a,10b,10c