NCC 2022 Volume One - Building Code of Australia Class 2 to 9 buildings
Search the National Construction Code editions
Referenced documents
The Standards and other documents listed in this Schedule are referenced in the NCC.
No. | Date | Title | Volume One | Volume Two | Housing Provisions | Volume Three |
---|---|---|---|---|---|---|
AS/NZS ISO 717 Part 1 | 2004 | Acoustics — Rating of sound insulation in buildings and of building elements — Airborne sound insulation. (See Note 1) | F7V1, F7V2, F7V3, F7V4, F7D3 | H4V4 | 10.7.2 | N/A |
AS ISO 717 Part 2 | 2004 | Acoustics — Rating of sound insulation in buildings and of building elements — Impact sound insulation | F7V1, F7V3, F7D4 | N/A | N/A | N/A |
AS 1056 Part 1 | 1991 | Storage water heaters — General requirements (incorporating amendments 1, 2, 3, 4 and 5) | N/A | N/A | N/A | B2D2 |
AS/NZS 1170 Part 0 | 2002 | Structural design actions — General principles (incorporating amendments 1, 3 and 4) | B1V1, B1D2, Spec 4 | H1V1, H1D7 | 2.2.2 | N/A |
AS/NZS 1170 Part 1 | 2002 | Structural design actions — Permanent, imposed and other actions (incorporating amendments 1 and 2) | B1D3 | N/A | 2.2.3, 2.2.4, 8.3.1, 11.2.2, 11.2.3, 11.3.4 | N/A |
AS/NZS 1170 Part 2 | 2021 | Structural design actions — Wind actions | B1D3, B1D4, Spec 4, F3V1, Schedule 1 | H1D7, H2V1, Schedule 1 | 2.2.3, Schedule 1 | Schedule 1 |
AS/NZS 1170 Part 3 | 2003 | Structural design actions — Snow and ice actions (incorporating amendments 1 and 2) | B1D3 | N/A | 2.2.3 | |
AS 1170 Part 4 | 2007 | Structural design actions — Earthquake actions in Australia (incorporating amendments 1 and 2) | B1D3 | H1D4, H1D5, H1D6, H1D9 | 2.2.3 | N/A |
AS 1191 | 2002 | Acoustics — Method for laboratory measurement of airborne sound transmission insulation of building elements | Spec 29 | N/A | N/A | N/A |
AS 1273 | 1991 | Unplasticized PVC (UPVC) downpipe and fittings for rainwater | N/A | N/A | 7.4.2 | N/A |
AS 1288 | 2021 | Glass in buildings — Selection and installation | B1D4, Spec 11, Spec 12 | H1D8 | 8.3.1 | N/A |
AS 1289.6.3.3 | 1997 | Methods of testing soils for engineering purposes — Method 6.3.3: Soil strength and consolidation tests — Determination of the penetration resistance of a soil — Perth sand penetrometer test (incorporating amendment 1) | N/A | N/A | 4.2.4 | N/A |
AS 1397 | 2021 | Continuous hot-dip metallic coated steel sheet and strip — Coatings of zinc and zinc alloyed with aluminium and magnesium (See Note 10) | N/A | N/A | 7.2.2 | N/A |
AS 1428 Part 1 | 2009 | Design for access and mobility — General requirements for access — New building work (incorporating amendments 1 and 2) | D3D11, D3D16, D3D22, D4D2, D4D3, D4D4, D4D7, D4D10, D4D11, D4D13, Spec 16, E3D10, F4D5, G4D5, Schedule 1 | Schedule 1 | Schedule 1 | Schedule 1, E1D2 |
AS 1428 Part 1 | 2001 | Design for access and mobility — General requirements for access — New building work | I2D7, I2D8, I2D10, I2D15 | N/A | N/A | E1D2 |
AS 1428 Part 1 (Supplement 1) | 1993 | Design for access and mobility — General requirements for access — Buildings — Commentary | I2D2 | N/A | N/A | N/A |
AS 1428 Part 2 | 1992 | Design for access and mobility — Enhanced and additional requirements — Buildings and facilities | I2D2, I2D3, I2D4, I2D5, I2D7, I2D10, I2D11, I2D12, I2D13, I2D14 | N/A | N/A | E1D2 |
AS 1428 Part 4 | 1992 | Design for access and mobility — Tactile ground surface indicators for the orientation of people with vision impairment | I2D11 | N/A | N/A | N/A |
AS/NZS 1428 Part 4.1 | 2009 | Design for access and mobility — Means to assist the orientation of people with vision impairment — Tactile ground surface indicators (incorporating amendments 1 and 2) | D4D9 | N/A | N/A | N/A |
AS 1530 Part 1 | 1994 | Methods for fire tests on building materials, components and structures — Combustibility test for materials | Schedule 1 | Schedule 1 | Schedule 1 | Schedule 1 |
AS 1530 Part 2 | 1993 | Methods for fire tests on building materials, components and structures — Test for flammability of materials (incorporating amendment 1) | Schedule 1 | Schedule 1 | Schedule 1 | Schedule 1 |
AS/NZS 1530 Part 3 | 1999 | Methods for fire tests on building materials, components and structures — Simultaneous determination of ignitability, flame propagation, heat release and smoke release | Schedule 1, Spec 3 | Schedule 1, Spec 3 | Schedule 1 | Schedule 1, Spec 3 |
AS 1530 Part 4 | 2014 | Methods for fire tests on building materials, components and structures — Fire resistance tests for elements of construction | C4D15, C4D16, Spec 9, Spec 10, Spec 13, Spec 14, Schedule 1, Spec 3 | 9.3.2, Schedule 1, Spec 3 | Schedule 1 | Schedule 1, Spec 3 |
AS 1530 Part 8.1 | 2018 | Methods for fire tests on building materials, components and structures — Tests on elements of construction for buildings exposed to simulated bushfire attack — Radiant heat and small flaming sources | Spec 43 | N/A | N/A | N/A |
AS/NZS 1546 Part 1 | 2008 | On-site domestic wastewater treatment units - Septic tanks | N/A | N/A | N/A | C3D2 |
AS/NZS 1546 Part 2 | 2008 | On-site domestic wastewater treatment units - Waterless composting toilets | N/A | N/A | N/A | C3D3 |
AS 1546 Part 3 | 2017 | On-site domestic wastewater treatment units - Secondary treatment systems (incorporating amendment 1) | N/A | N/A | N/A | C3D4 |
AS 1546 Part 4 | 2016 | On-site domestic wastewater treatment units - Domestic greywater treatment systems | N/A | N/A | N/A | C3D5 |
AS/NZS 1547 | 2012 | On-site domestic wastewater management | N/A | N/A | N/A | C3D6 |
AS 1562 Part 1 | 2018 | Design and installation of sheet roof and wall cladding — Metal (See Note 2) | B1D4, F3D2, F3D5 | H1D7 | N/A | N/A |
AS1562 Part 3 | 2006 | Design and installation of sheet roof and wall cladding — Plastic | B1D4, F3D2 | H1D7 | N/A | N/A |
AS 1657 | 2018 | Fixed platforms, walkways, stairways and ladders — Design, construction and installation | D2D21, D2D22, D3D23, I1D6, I3D5 | N/A | N/A | N/A |
AS/NZS 1664 Part 1 | 1997 | Aluminium structures — Limit state design (incorporating amendment 1) | B1D4 | N/A | 2.2.4 | N/A |
AS/NZS 1664 Part 2 | 1997 | Aluminium structures — Allowable stress design (incorporating amendment 1) | B1D4 | N/A | 2.2.4 | N/A |
AS 1668 Part 1 | 2015 | The use of ventilation and air conditioning in buildings — Fire and smoke control in buildings (incorporating amendment 1) | C3D13, C4D15, Spec 11, D2D12, Spec 19, E2D3, E2D4, E2D6, E2D7, E2D8, E2D9, E2D11, E2D12, E2D13, E2D16, E2D17, E2D19, F6D12, Spec 21, Spec 31 | N/A | N/A | N/A |
AS 1668 Part 2 | 2012 | The use of ventilation and air conditioning in buildings — Mechanical ventilation in buildings (incorporating amendments 1 and 2) | E2D12, F6V1, F6D6, F6D11, F6D12, F8D4, J6D4 | H4V3, H4D7 | 10.8.2 | N/A |
AS 1668 Part 4 | 2012 | The use of ventilation and air conditioning in buildings — Natural ventilation of buildings | F6D11 | N/A | N/A | N/A |
AS 1670 Part 1 | 2018 | Fire detection, warning, control and intercom systems — System design, installation and commissioning — Fire (incorporating amendment 1) (See Note 3) | C4D6, C4D7, C4D8, C4D9, C4D12, D3D26, E2D3, E2D10, G4D7, Spec 12, Spec 20, Spec 23, Spec 31 | N/A | 9.5.1 | N/A |
AS 1670 Part 3 | 2018 | Fire detection, warning, control and intercom systems — System design, installation and commissioning — Fire alarm monitoring (incorporating amendment 1) (See Note 3) | Spec 20, Spec 23 | N/A | N/A | N/A |
AS 1670 Part 4 | 2018 | Fire detection, warning, control and intercom systems — System design, installation and commissioning — Emergency warning and intercom systems (incorporating amendment 1) (See Note 3) | E3V2, E4D9, Spec 31 | N/A | N/A | N/A |
AS/NZS 1680 Part 0 | 2009 | Interior lighting — Safe movement | F6D5 | N/A | 10.5.2 | N/A |
AS 1684 Part 2 | 2021 | Residential timber-framed construction — Non-cyclonic areas | B1D4, B1D5, F1D8 | H1D6 | 2.2.5, 4.2.13, 5.6.6, 6.2.1, 6.3.6, 7.5.2, 7.5.3, 7.5.4, 10.2.19, 10.2.20 | N/A |
AS 1684 Part 3 | 2021 | Residential timber-framed construction — Cyclonic areas | B1D4, B1D5, F1D8 | H1D6 | 2.2.5, 4.2.13, 5.6.6, 6.2.1, 6.3.6, 7.5.2, 7.5.3, 7.5.4, 10.2.19, 10.2.20 | N/A |
AS 1684 Part 4 | 2010 | Residential timber-framed construction — Simplified — Non-cyclonic areas (incorporating amendment 1) | B1D4, B1D5, F1D8 | H1D6 | 2.2.5, 4.2.13, 5.6.6, 6.2.1, 7.5.2, 7.5.3, 7.5.4, 10.2.19, 10.2.20 | N/A |
AS 1720 Part 1 | 2010 | Timber structures — Design methods (incorporating amendments 1, 2 and 3) | B1V1, B1D4 | H1V1, H1D6 | 4.2.13, 5.3.3 | N/A |
AS/NZS 1720 Part 4 | 2019 | Timber structures — Fire resistance of timber elements | Spec 1 | Spec 1 | N/A | Spec 1 |
AS 1720 Part 5 | 2015 | Timber structures — Nailplated timber roof trusses (incorporating amendment 1) | B1D4 | H1D6 | N/A | N/A |
AS 1735 Part 11 | 1986 | Lifts, escalators and moving walks — Fire rated landing doors | C4D11 | N/A | N/A | N/A |
AS 1735 Part 12 | 1999 | Lifts, escalators and moving walks — Facilities for persons with disabilities (incorporating amendment 1) | E3D8, I2D6 | N/A | N/A | N/A |
AS/NZS 1859 Part 4 | 2018 | Reconstituted wood based panels — Specifications — Wet process fibreboard | N/A | N/A | 7.5.3, 7.5.4 | N/A |
AS 1860 Part 2 | 2006 | Particleboard flooring — Installation (incorporating amendment 1) | B1D4 | H1D6 | N/A | N/A |
AS 1905 Part 1 | 2015 | Components for the protection of openings in fire-resistant walls — Fire-resistant doorsets (incorporating amendment 1) | C4D7, Spec 12 | N/A | N/A | N/A |
AS 1905 Part 2 | 2005 | Components for the protection of openings in fire-resistant walls — Fire-resistant roller shutters | Spec 12 | N/A | N/A | N/A |
AS 1926 Part 1 | 2012 | Swimming pool safety — Safety barriers for swimming pools | G1D2, G1D4 | H7D2 | N/A | N/A |
AS 1926 Part 2 | 2007 | Swimming pool safety — Location of safety barriers for swimming pools (incorporating amendments 1 and 2) | G1D2 | H7D2 | N/A | N/A |
AS 1926 Part 3 | 2010 | Swimming pool safety — Water recirculation systems (incorporating amendment 1) | G1D2 | H7D2 | N/A | N/A |
AS 2047 | 2014 | Windows and external glazed doors in buildings (incorporating amendments 1 and 2) (See Note 4) | B1D4, F3V1, F3D4, J5D5 | H1D8, H2V1 | 13.4.4 | N/A |
AS 2049 | 2002 | Roof tiles (incorporating amendment 1) | F3D2 | H1D7 | N/A | N/A |
AS 2050 | 2018 | Installation of roof tiles | B1D4, F3D2 | H1D7 | 7.3.2 | N/A |
AS 2118 Part 1 | 2017 | Automatic fire sprinkler systems — General systems (incorporating amendments 1 and 2) | C1V3, Spec 17, Spec 18 | N/A | N/A | N/A |
AS 2118 Part 4 | 2012 | Automatic fire sprinkler systems — Sprinkler protection for accommodation buildings not exceeding four storeys in height | Spec 17, Spec 18 | N/A | N/A | B4D3 |
AS 2118 Part 5 | 2008 (R 2020) | Automatic fire sprinkler systems - Home fire sprinkler systems | N/A | N/A | N/A | B4D3 |
AS 2118 Part 6 | 2012 | Automatic fire sprinkler systems — Combined sprinkler and hydrant systems in multistorey buildings | Spec 17 | N/A | N/A | B4D3 |
AS 2159 | 2009 | Piling — Design and installation (incorporating amendment 1) | B1D4 | H1D12 | N/A | N/A |
AS/NZS 2179 Part 1 | 2014 | Specifications for rainwater goods, accessories and fasteners — Metal shape or sheet rainwater goods, and metal accessories and fasteners | N/A | N/A | 7.4.2 | N/A |
AS/NZS 2269 Part 0 | 2012 | Plywood — Structural — Specifications (incorporating amendment 1) | N/A | N/A | 7.5.4 | N/A |
AS/NZS 2293 Part 1 | 2018 | Emergency lighting and exit signs for buildings — System design, installation and operation (incorporating amendment 1) | E4D4, E4D8, Spec 25, I3D15 | N/A | N/A | N/A |
AS 2312 Part 1 | 2014 | Guide to the protection of structural steel against atmospheric corrosion by the use of protective coatings — Paint coatings | N/A | N/A | 6.3.9 | N/A |
AS/NZS 2312 Part 2 | 2014 | Guide to the protection of structural steel against atmospheric corrosion by the use of protective coatings — Hot dip galvanizing | N/A | N/A | 6.3.9 | N/A |
AS/NZS 2327 | 2017 | Composite structures — Composite steel-concrete construction in buildings (incorporating amendment 1) | B1D4, Spec 1 | Spec 1 | 2.2.4 | Spec 1 |
AS 2419 Part 1 | 2021 | Fire hydrant installations — System design, installation and commissioning | C3D13, E1D2, Spec 18, I3D9 | N/A | N/A | B4D4 |
AS 2441 | 2005 | Installation of fire hose reels (incorporating amendment 1) | E1D3 | N/A | N/A | B4D5 |
AS 2444 | 2001 | Portable fire extinguishers and fire blankets — Selection and location | E1D14, I3D11 | N/A | N/A | N/A |
AS 2665 | 2001 | Smoke/heat venting systems — Design, installation and commissioning | Spec 22, Spec 31 | N/A | N/A | N/A |
AS 2699 Part 1 | 2020 | Built-in components for masonry construction — Wall ties (See Note 9) | C2D10 | N/A | 5.6.5 | N/A |
AS 2699 Part 3 | 2020 | Built-in components for masonry construction — Lintels and shelf angles (durability requirements) (See Note 9) | C2D10 | N/A | 5.6.7 | N/A |
AS 2870 | 2011 | Residential slabs and footings | F1D7 | H1D4, H1D5 | 3.4.2, 4.2.2, 4.2.6, 4.2.8, 4.2.11, 4.2.14, 4.2.15, 10.2.9 | N/A |
AS/NZS 2890 Part 6 | 2009 | Parking facilities — Offstreet parking for people with disabilities | D4D6 | N/A | N/A | N/A |
AS/NZS 2904 | 1995 | Damp-proof courses and flashings (incorporating amendments 1 and 2) | F1D6 | N/A | 5.7.3, 7.5.6, 12.3.3 | N/A |
AS/NZS 2908 Part 1 | 2000 | Cellulose-cement products — Corrugated sheets | B1D4 | N/A | N/A | N/A |
AS/NZS 2908 Part 2 | 2000 | Cellulose-cement products — Flat sheets | Schedule 1 | Schedule 1 | 7.5.3, 7.5.4, 7.5.5, 10.2.9,10.2.10, Schedule 1 | Schedule 1 |
AS/NZS 2918 | 2018 | Domestic solid fuel burning appliances — Installation (See Note 8) | G2D2 | H7D5 | 12.4.4, 12.4.5 | N/A |
AS/NZS 3013 | 2005 | Electrical installations — Classification of the fire and mechanical performance of wiring system elements | C3D14 | N/A | N/A | N/A |
AS/NZS 3500 Part 0 | 2021 | Plumbing and drainage — Glossary of terms | A1G4 | A1G4 | N/A | A1G4 |
AS/NZS 3500 Part 1 | 2018 | Plumbing and drainage — Water services | N/A | N/A | N/A | B5D6 |
AS/NZS 3500 Part 1 | 2021 | Plumbing and drainage — Water services | N/A | N/A | N/A | B1D3, B1D5, B1D6, B3D3, B5V1, B5D2, B5D3, B5D4, Spec 41, B6D2, B6D3, B6D5, B7D3, |
AS/NZS 3500 Part 2 | 2021 | Plumbing and drainage — Sanitary plumbing and drainage (incorporating amendment 1) | N/A | N/A | N/A | C1D3, C1V1, C1V2, C1V3, C1V4, C1V5, C2V2, C2D3, C2D4, C3D7 |
AS/NZS 3500 Part 3 | 2021 | Plumbing and drainage — Stormwater drainage (See Note 11) | F1D3 | H2D2, H2D6 | 7.4.3 | N/A |
AS/NZS 3500 Part 4 | 2021 | Plumbing and drainage — Heated water services (incorporating amendment 1) | N/A | N/A | N/A | B2D2, B2D6, B2D7, B2D8, B2D9, B2D11 |
AS 3600 | 2018 | Concrete structures (incorporating amendments 1 and 2) | B1V1, B1D4, Spec 1 | H1V1, H1D4, Spec 1 | 3.4.2, 4.2.6, 4.2.10, 4.2.13, 5.3.3, 10.2.9 | Spec 1 |
AS 3660 Part 1 | 2014 | Termite management — New building work (incorporating amendment 1) | B1D4, F1D6 | N/A | 3.4.1, 3.4.2 | N/A |
AS 3660 Part 3 | 2014 | Termite management — Assessment criteria for termite management systems | N/A | N/A | 3.4.2 | N/A |
AS/NZS 3666 Part 1 | 2011 | Air-handling and water systems of buildings — Microbial control — Design, installation and commissioning | F4D10, F6D6 | N/A | N/A | N/A |
AS 3700 | 2018 | Masonry structures | B1D4, F3D5, Spec 1, Spec 2 | H1D5, H2D4, Spec 1, Spec 2 | 5.3.3, 5.4.2, 5.6.3, 6.3.6, 10.2.9, 10.2.19, 10.2.20, 12.4.3 | Spec 1, Spec 2 |
AS 3740 | 2021 | Waterproofing of domestic wet areas | F2D2 | H4D2, H4D3 | 10.2.20 | N/A |
AS 3786 | 2014 | Smoke alarms using scattered light, transmitted light or ionization (incorporating amendment 1 and 2) (See Note 5) | Spec 20 | N/A | 9.5.1 | N/A |
AS/NZS 3823 Part 1.2 | 2012 | Performance of electrical appliances — Air conditioners and heat pumps — Ducted air conditioners and air-to-air heat pumps — Testing and rating for performance | Spec 33, J6D12 | N/A | N/A | N/A |
AS 3959 | 2018 | Construction of buildings in bushfire-prone areas (incorporating amendments 1 and 2) | C2D14, F8D5, G5D2, G5D3, Spec 43 | H7D4 | 10.8.3 | B1D4, B2D10, B3D4, C1D4, C2D5 |
AS/NZS 4020 | 2018 | Testing of products for use in contact with drinking water (See Note 6) | A5G4 | A5G4 | N/A | A5G4 |
AS 4055 | 2021 | Wind loads for housing | Schedule 1 | H1D6, H1D8, Schedule 1 | 2.2.3, Schedule 1 | Schedule 1 |
AS 4072 Part 1 | 2005 | Components for the protection of openings in fire-resistant separating elements — Service penetrations and control joints (incorporating amendment 1) | C4D15, C4D16 | N/A | 9.3.2 | N/A |
AS 4100 | 2020 | Steel structures | B1D4, Spec 1 | H1D6, Spec 1 | 4.2.13, 5.6.7 | Spec 1 |
AS 4200 Part 1 | 2017 | Pliable building membranes and underlays — Materials (incorporating amendment 1) | F3D3, F8D3, Spec 36, Schedule 1 | Schedule 1 | 7.3.4, 7.5.2, 7.5.8, 10.8.1, Schedule 1 | Schedule 1 |
AS 4200 Part 2 | 2017 | Pliable building membranes and underlays — Installation requirements (incorporating amendments 1 and 2) | F3D3, F8D3 | N/A | 10.8.1 | N/A |
AS/NZS 4234 | 2021 | Heated water systems — Calculation of energy consumption | Spec 45 | N/A | N/A | B2D2 |
AS 4254 Part 1 | 2021 | Ductwork for air-handling systems in buildings — Flexible duct | Spec 7, J6D7 | H3D2 | 13.7.4 | N/A |
AS 4254 Part 2 | 2012 | Ductwork for air-handling systems in buildings — Rigid duct | Spec 7, J6D5, J6D7 | N/A | 13.7.4 | N/A |
AS/NZS 4284 | 2008 | Testing of building facades | F3V1 | H2V1 | N/A | N/A |
AS/NZS 4505 | 2012 | Garage doors and other large access doors (incorporating amendment 1) | B1D4 | N/A | 2.2.4 | N/A |
AS 4552 | 2005 | Gas fired water heaters for hot water supply and/or central heating | N/A | N/A | N/A | B2D2 |
AS 4586 | 2013 | Slip resistance classification of new pedestrian surface materials (incorporating amendment 1) (See Note 7) | D3D11, D3D14, D3D15. Spec 27 | N/A | 11.2.4 | N/A |
AS 4597 | 1999 | Installation of roof slates and shingles (Non-interlocking type) | B1D4, F3D2 | H1D7 | N/A | N/A |
AS/NZS 4600 | 2018 | Cold-formed steel structures | B1D4, Spec 1 | H1D6, Spec 1 | 5.3.3, 6.3.6 | Spec 1 |
AS 4654 Part 1 | 2012 | Waterproofing membranes for external above-ground use — Materials | F1D5 | H2D8 | N/A | N/A |
AS 4654 Part 2 | 2012 | Waterproofing membranes for external above-ground use — Design and installation | C2D14, F1D4, F1D5 | H2D8 | N/A | N/A |
AS 4678 | 2002 | Earth-retaining structures | N/A | H1D3 | N/A | N/A |
AS 4773 Part 1 | 2015 | Masonry in small buildings — Design (incorporating amendment 1) | N/A | H1D5, H2D4 | 5.6.3, 12.4.3 | N/A |
AS 4773 Part 2 | 2015 | Masonry in small buildings — Construction (incorporating amendment 1) | N/A | H1D5, H2D4 | 5.6.3, 12.4.3 | N/A |
AS/NZS 4859 Part 1 | 2018 | Thermal insulation materials for buildings — General criteria and technical provisions | J4D3, J6D6, J6D9 | N/A | 13.2.2, 13.7.2, 13.7.4 | N/A |
AS/NZS 4859 Part 2 | 2018 | Thermal insulation materials for buildings — Design | J3D8, J4D3, Spec 36, Spec 37 | N/A | 13.2.5, 13.2.6 | N/A |
AS/NZS 4858 | 2004 | Wet area membranes | N/A | N/A | 10.2.8 | N/A |
AS 5113 | 2016 | Classification of external walls of buildings based on reaction-to-fire performance (incorporating amendment 1) | C1V3 | N/A | N/A | N/A |
AS 5146 Part 1 | 2015 | Reinforced autoclaved aerated concrete — Structures (incorporating amendment 1) | B1D4 | H1D7 | N/A | N/A |
AS 5146 Part 3 | 2018 | Reinforced autoclaved aerated concrete — Construction | B1D4, F3D5 | N/A | N/A | N/A |
AS 5216 | 2021 | Design of post-installed and cast-in fastenings in concrete | B1D4 | N/A | 2.2.4 | N/A |
AS/NZS 5601 Part 1 | 2013 | Gas installations — General installations | J1V4 | H6V3 | N/A | N/A |
AS 5637 Part 1 | 2015 | Determination of fire hazard properties — Wall and ceiling linings | Spec 7, Schedule 1 | Schedule 1 | Schedule 1 | Schedule 1 |
AS ISO 9239 Part 1 | 2003 | Reaction to fire tests for floorings — Determination of the burning behaviour using a radiant heat source | Schedule 1 | Schedule 1 | Schedule 1 | Schedule 1 |
AS/NZS ISO 9972 | 2015 | Thermal performance of buildings — Determination of air permeability of buildings — Fan pressurization method | J1V4 | H6V3 | N/A | N/A |
AIRAH-DA07 | 2021 | Criteria for moisture control design analysis in buildings | F8V1 | H4V5 | N/A | N/A |
AIRAH-DA09 | 1998 | Air conditioning load estimation | Spec 35 | N/A | N/A | N/A |
AIRAH-DA28 | 2011 | Building management and control systems | Spec 34 | N/A | N/A | N/A |
ANSI/ASHRAE Standard 55 | 2013 | Thermal environmental conditions for human occupancy | Schedule 1 | Schedule 1 | Schedule 1 | Schedule 1 |
ANSI/ASHRAE Standard 140 | 2007 | Standard method of test for the evaluation of building energy analysis computer programs | J1V1, J1V2, J1V3, J1V5 | H6V2 | N/A | N/A |
ASTM E2073-10 | 2010 | Standard Test Method for Photopic Luminance of Photoluminescent (Phosphorescent) Markings | Spec 25 | N/A | N/A | N/A |
ASTM E72-15 | 2015 | Standard Test Methods of Conducting Strength Tests of Panels for Building Construction | Spec 6 | N/A | N/A | N/A |
ASTM E695-03 | 2003 | Standard Test Method of Measuring Relative Resistance of Wall, Floor and Roof Construction to Impact Loading | Spec 6 | N/A | N/A | N/A |
ASTM E96 | 2016 | Standard Test Methods for Water Vapor Transmission of Materials | Schedule 1 | Schedule 1 | Schedule 1 | Schedule 1 |
AHRI 460 | 2005 | Performance rating of remote mechanical-draft air-cooled refrigerant condensers | J6D13 | N/A | N/A | N/A |
AHRI 551/591 | 2015 | Performance rating of water-chilling and heat pump water-heating packages using the vapor compression cycle. | Spec 33, J6D11 | N/A | N/A | N/A |
ABCB | 2022 | Fire Safety Verification Method | C1V4 | N/A | N/A | N/A |
ABCB | 2022 | Housing Provisions Standard | N/A | Throughout | Throughout | N/A |
ABCB | 2022 | Livable Housing Design | G7D2 | H4D3, H8D2 | 3.3.3, 11.2.3 | N/A |
ABCB | 2011 | Protocol for Structural Software, Version 2011.2 | B1D5 | H1D6 | 2.2.5 | N/A |
ABCB | 2012 | Standard for Construction of Buildings in Flood Hazard Areas, Version 2012.3 | B1D6 | H1D10 | N/A | N/A |
ABCB | 2022 | Standard for NatHERS Heating and Cooling Load Limits, Version 2022.1 | J3D3 | Spec 42 | N/A | N/A |
ABCB | 2022 | Standard for Whole-of-Home Efficiency Factors | J3D14 | N/A | 13.6.2 | N/A |
CIBSE Guide A | 2015 | Environmental design | Spec 34, Spec 35, J4D3, J4D7 | N/A | N/A | N/A |
N/A | 2002 | Disability Standards for Accessible Public Transport | F4D12, I2D1 | N/A | N/A | N/A |
N/A | 2010 | Education and Care Services National Law Act (Vic) | Schedule 1 | Schedule 1 | Schedule 1 | Schedule 1 |
European Union Commission Regulation 547/2012 | 2012 | Eco-design requirements for water pumps | J6D8 | N/A | N/A | N/A |
European Union Commission Regulation 622/Annexx II, point 2 | 2012 | Eco-design requirements for glandless standalone circulators and glandless circulators integrated in products | J6D8 | N/A | N/A | N/A |
FPAA101D | 2021 | Automatic Fire Sprinkler System Design and Installation — Drinking Water Supply | C1V3, C2D6, C2D13, C3D2, C3D7, C3D8, C4D6, C4D7, C4D8, C4D9, C4D12, Spec 5, Spec 7, D2D4, D2D17, D3D26, D3D30, E2D8, E2D9, E2D13, E2D14, E2D15, E2D16, E2D17, E2D19, E2D20, Spec 17, Spec 18, Spec 20, G3D1, G3D6, Spec 31, I1D2, Schedule 1 | Schedule 1 | Schedule 1 | B4D3, Schedule 1, B1D5 |
FPAA101H | 2018 | Automatic Fire Sprinkler System Design and Installation — Hydrant Water Supply (incorporating amendment 1) | C1V3, C2D6, C2D13, C3D2, C3D7, C3D8, Spec 5, Spec 7, Spec 17, Spec 18, E2D8, E2D9, E2D13, E2D14, E2D15, E2D16, E2D17, E2D19, E2D20, Spec 20, G3D1, G3D6, Spec 31, I1D2 | N/A | N/A | B4D3 |
ISO 140 Part 6 | 1998E | Acoustics — Measurement of sound insulation in buildings and of building elements — Laboratory measurements of impact sound insulation of floors | Spec 29 | N/A | N/A | N/A |
ISO 540 | 2008 | Hard coal and coke — Determination of ash fusibility | Spec 13 | N/A | N/A | N/A |
ISO 8336 | 1993E | Fibre-cement flat sheets | Schedule 1 | Schedule 1 | 7.5.3, 7.5.4, 7.5.5, Schedule 1 | Schedule 1 |
ISO 25745 Part 2 | 2015 | Energy performance of lifts, escalators and moving walks: Energy calculation and classification for lifts (elevators) | J7D8 | N/A | N/A | N/A |
NASH Standard | 2021 | Steel Framed Construction in Bushfire Areas | N/A | H7D4 | N/A | N/A |
NASH Standard Part 1 | 2005 | Residential and Low Rise Steel Framing — Design Criteria (incorporating amendments A, B and C) | B1D4 | H1D6 | N/A | N/A |
NASH Standard Part 2 | 2014 | Residential and Low Rise Steel Framing — Design Solutions (incorporating amendment A) | B1D4, B1D5, F1D8 | H1D6 | 2.2.5, 6.2.1, 6.3.6, 7.5.2, 7.5.3, 7.5.4, 10.2.19, 10.2.20 | N/A |
NSF/ ANSI/ CAN 372 | 2020 | Drinking Water System Components - Lead Content | A5G4 | A5G4 | N/A | A5G4 |
N/A | N/A | Northern Territory Deemed to Comply Standards Manual | N/A | N/A | 2.2.4 | N/A |
SA TS 5344 | 2019 | Permanent labelling for Aluminium Composite Panel (ACP) products | A5G8 | A5G8 | N/A | A5G8 |
TN 61 | N/A | Cement Concrete and Aggregates Australia — Technical note — Articulated walling | N/A | H1D4 | N/A | N/A |
WMK NOD 2021/4.2 | 2021 | WaterMark Notice of Direction 2021/4.2 Certification transition arrangements for lead free plumbing products | A5G4 | A5G4 | N/A | A5G4 |